Variables
PowerModelsProtection.variable_branch_current
— Methodvariable_branch_current(pm::_PM.AbstractIVRModel; nw::Int=nw_id_default, bounded::Bool=true, report::Bool=true, kwargs...)
Copies from PowerModels and PowerModelsDistribution without power vars
PowerModelsProtection.variable_bus_fault_current
— Methodvariable_bus_fault_current(pm::_PM.AbstractIVRModel; nw::Int=nw_id_default, report::Bool=true)
fault current variables for active faults
PowerModelsProtection.variable_gen
— Methodvariable_gen(pm::_PM.AbstractIVRModel; nw::Int=nw_id_default, bounded::Bool=true, report::Bool=true, kwargs...)
builds generator variables for transmission networks
PowerModelsProtection.variable_gen_loading
— Methodvariable_gen_loading(pm::_PM.AbstractIVRModel; nw::Int=nw_id_default, bounded::Bool=true, report::Bool=true)
variable: pg[j]
for j
in gen
PowerModelsProtection.variable_mc_bus_fault_current
— Methodvariable_mc_bus_fault_current(pm::_PMD.AbstractUnbalancedIVRModel; nw::Int=nw_id_default, report::Bool=true)
variables for multiconductor fault currents for active faults
PowerModelsProtection.variable_mc_grid_formimg_inverter
— Methodvariable_mc_grid_formimg_inverter(pm::_PMD.AbstractUnbalancedIVRModel; nw::Int=nw_id_default, bounded::Bool=true, kwargs...)
variables for multiconductor grid forming inverters
PowerModelsProtection.variable_mc_pq_inverter
— Methodvariable_mc_pq_inverter(pm::_PMD.AbstractUnbalancedIVRModel; nw::Int=nw_id_default, bounded::Bool=true, kwargs...)
variables for multiconductor pq inverters
PowerModelsProtection.variable_mc_storage_current
— Methodvariable_mc_storage_current(pm::_PMD.AbstractUnbalancedIVRModel; nw::Int=nw_id_default, bounded::Bool=true, report::Bool=true)
variables for output terminal currents for grid-connected energy storage
PowerModelsProtection.variable_mc_storage_current_imaginary
— Methodvariable_mc_storage_current_imaginary(pm::_PMD.AbstractUnbalancedIVRModel; nw::Int=nw_id_default, bounded::Bool=true, report::Bool=true)
variables for real portion of output terminal currents for grid-connected energy storage
PowerModelsProtection.variable_mc_storage_current_real
— Methodvariable_mc_storage_current_real(pm::_PMD.AbstractUnbalancedIVRModel; nw::Int=nw_id_default, bounded::Bool=true, report::Bool=true)
variables for real portion of output terminal currents for grid-connected energy storage
PowerModelsProtection.variable_mc_storage_grid_forming_inverter
— Methodvariable_mc_storage_grid_forming_inverter(pm::_PMD.AbstractUnbalancedIVRModel; nw::Int=nw_id_default, bounded::Bool=true, kwargs...)
variables associated with grid-connected energy storage: internal voltage, virutal impedance, dc-link power, faulted state
PowerModelsProtection.variable_pq_inverter
— Methodvariable_pq_inverter(pm::_PM.AbstractIVRModel; nw::Int=nw_id_default, bounded::Bool=true, kwargs...)
variables for pq inverters